Standard Detail Drawings

All Standard Detail Drawings presented herein are intended to assist architects, engineers, other design professionals, contractors and UT staff in understanding the preferences of The University of Texas at Austin in the development, maintenance, construction and repair of its facilities. These Detail Drawings are intended to be used as guidelines. Detail Drawing documents require modification to meet the conditions and appurtenances of each project; therefore the legal responsibility for project document preparation shall continue to reside with the Design Professional. Refer to the Welcome Page for additional requirements. The Detail Drawings were created in AutoCAD 2007 file format; AutoCAD is a registered trademark of Autodesk Inc.

Important: These Detail Drawing documents are for use by The University of Texas at Austin and its consultants and contractors. Drawings remain the property of The University of Texas at Austin at all times.

Viewing Note: The CAD (DWG) files will not open in a browser, you have to save them to the your desktop.

Division 22: Standard Detail Drawings

SectionTitleCAD FilesPDF
P-22-1-3FLOOR DRAIN INSTALLATION DETAILP-22-1-3P-22-1-3
P-22-1-4FLOOR DRAIN INSTALLATION DETAILP-22-1-4P-22-1-4
P-22-1-12FLOOR DRAIN INSTALLATION DETAILP-22-1-12P-22-1-12
P-22-1-13FLOOR DRAIN INSTALLATION DETAILP-22-1-13P-22-1-13
P-22-2-2PIPE SUPPORT DETAILP-22-2-2P-22-2-2
P-22-2-5PIPE SUPPORT DETAILP-22-2-5P-22-2-5
P-22-2-6MODULAR COMPRESSION PIPE SEAL AND SLEEVE DETAILP-22-2-6P-22-2-6
P-22-2-7PIPE SLEEVE DETAILSP-22-2-7P-22-2-7
P-22-2-8WATER, WASTE & VENT PIPING HANGERS & SUPPORTS DETAILP-22-2-8P-22-2-8
P-22-5-1LAVATORY & SINK CONNECTION DETAILP-22-5-1P-22-5-1
P-22-5-5LAVATORY & SINK CONNECTION DETAILP-22-5-5P-22-5-5
P-22-5-6DETAIL: LAB SINK CONNECTIONP-22-5-6P-22-5-6

Division 23: Standard Detail Drawings

SectionTitleCAD FilesPDF
M-23-1-5TYPICAL BRANCH DUCT WITH 45° CLINCH TAP DETAILM-23-1-5M-23-1-5
M-23-1-6TYPICAL BRANCH DUCT WITH CONICAL TAP DETAILM-23-1-6M-23-1-6
M-23-1-10LINED SOUND PLENUMM-23-1-10M-23-1-10
M-23-1-19CEILING FIRE DAMPER DETAILM-23-1-19M-23-1-19
M-23-1-20FIRE DAMPER INSTALLATION DETAILM-23-1-20M-23-1-20
M-23-1-28LATERAL MIXING TEE DETAILM-23-1-28M-23-1-28
M-23-1-32VAV FUME HOOD DETAIL (BUILDINGS WITH PNEUMATIC CONTROLS)M-23-1-32M-23-1-32
M-23-3-1WATER PIPING HANGERS AND SUPPORTS DETAILM-23-3-1M-23-3-1
M-23-3-2PIPE SLEEVE DETAILM-23-3-2M-23-3-2
M-23-3-3WATER PIPING HANGERS AND SUPPORTS DETAILM-23-3-3M-23-3-3
M-23-3-4PIPE THRU ROOF DETAILM-23-3-4M-23-3-4
M-23-4-2STEAM HEATING COIL PIPING DIAGRAM REHEAT POSITIONM-23-4-2M-23-4-2
M-23-4-2-ASTEAM HEATING COIL PIPING DIAGRAM PREHEAT POSITIONM-23-4-2-AM-23-4-2-A
M-23-4-8PIPING SCHEMATIC: STEAM COILM-23-4-8M-23-4-8
M-23-4-10SERIES CHILLED WATER COIL PIPING DIAGRAMM-23-4-10M-23-4-10
M-23-4-17CHILLED WATER INSULATION DETAIL AT AHU COILM-23-4-17M-23-4-17
M-23-4-18CONDENSATE DRAIN DETAILM-23-4-18M-23-4-18
M-23-4-19SCHEMATIC AIR BLEED/TEST VALVE SCHEMATICM-23-4-19M-23-4-19
M-23-4-23PIPING DIAGRAM: STEAM TRAP AT END OF MAINM-23-4-23M-23-4-23
M-23-4-25INSTRUMENT TAPS IN PIPING DETAILM-23-4-25M-23-4-25
M-23-4-27SPLIT CHILLED WATER COIL PIPING DIAGRAMM-23-4-27M-23-4-27
M-23-4-31INSTRUMENTATION & MISCELLANEOUS PIPING TAPS (FOR WATER BELOW AMBIENT TEMP)M-23-4-31M-23-4-31
M-23-4-34COOLING COIL MOUNTING DETAILSM-23-4-34M-23-4-34
M-23-5-8STEAM CONDENSATE TANK & DUPLEX PUMP DETAILM-23-5-8M-23-5-8
M-23-5-10END SUCTION PUMP PIPING DETAILM-23-5-10M-23-5-10
M-23-6-1AHU - FRONT ACCESS FILTER HOUSING DETAILM-23-6-1M-23-6-1
M-23-8-3MIXING LATERAL CONTROL DIAGRAMM-23-8-3M-23-8-3
M-23-8-6LOW TEMPERATURE SAFETY MOUNTING DETAILM-23-8-6M-23-8-6
M-23-8-22THERMOSTAT & DAMPER CONTROLLER ASSEMBLY DETAILM-23-8-22M-23-8-22
M-23-8-23THERMOSTAT & DAMPER CONTROLLER ASSEMBLY DETAILM-23-8-23M-23-8-23

 

Division 23.UEM - Standard Detail Drawings

TitleCAD FilesPDF
UEM ADJUSTABLE PIPE FLOOR STANDDWGPDF
UEM CHW AND HHW DRAIN, VENT, AND AIR RELIEF VALVEDWGPDF
UEM CHW FLANGE AND VALVE FOAM INSULATIONDWGPDF
UEM CHW HDPE TO CARBON STEEL TRANSITIONDWGPDF
UEM DOUBLE-SUCTION HORIZONTAL SPLIT CASE PUMPDWGPDF
UEM ELBOW STANCHION ANCHORDWGPDF
UEM ELECTRIC-DRIVEN STEAM CONDENSATE RETURN UNITDWGPDF
UEM END-SUCTION PUMPDWGPDF
UEM HANGING PIPE SUPPORTDWGPDF
UEM PIPE PENETRATION THROUGH EXTERIOR WALLDWGPDF
UEM PIPE PENETRATION THROUGH FLOOR FROM GRADEDWGPDF
UEM PRESSURE POWERED STEAM CONDENSATE RETURN UNITDWGPDF
UEM STEAM AND CONDENSATE ROLLER PIPE SUPPORTDWGPDF
UEM STEAM DRIP LEG AND STEAM TRAP ASSEMBLYDWGPDF
UEM STEAM PRV STATIONDWGPDF
UEM VERTICAL PIPE ANCHORDWGPDF
UEM VERTICAL PIPE SUPPORTDWGPDF

 

 

Division 31.UEM - Standard Detail Drawings

TitleCAD FilesPDF
UEM TRENCH AND BACKFILLDWGPDF

 

Division 33.UEM - Standard Detail Drawings

TitleCAD FilesPDF
UEM BURIED CHW HDPE AUTO AIR VENTDWGPDF
UEM BURIED HHW STEEL AUTO AIR VENTDWGPDF
UEM GREASE TRAP DETAILDWGPDF
UEM SANITARY DOUBLE CLEANOUTDWGPDF
UEM SANITARY MANHOLE INTERNAL DROPDWGPDF
UEM STEAM CONDENSATE, STEAM, CHW, OR HHW PRESSURE INDICATOR TAPDWGPDF
UEM STEAM FLOW METERDWGPDF
UEM THERMAL, POTABLE, AND NON-POTABLE FLOW METERDWGPDF